45/84
2015/02 - Indice de révision : B - Code : 29650
by UV radiation and is not being consumed by
pollution introduced by bathers, therefore there
is a risk that it will accumulate in the water while
The two wires of the dry contact should be
connected to the COVER terminal in the control
panel (see paragraph IV), and the contact should
close when the cover is deployed over the pool.
AUX is displayed on the panel's LCD screen, and
the production of Chlorine is decreased to 20% by
default.
The value by which Chlorine production is decreased
user using the arrow keys
The new value will be saved automatically, this will
then be the Chlorine output in Cover mode until the
• DESCALING THE CELL BY INJECTING ACID USING THE PH-CLEAR PUMP
To cancel periodic injections of acid, set the level
LVL to 0.
Nota bene: for EES Pro the factory setting is LVL
= 9.
It is also possible to carry out an immediate injection
of acid, and to set the volume of acid to be injected:
•
• press the button twice to enter CELL
CLEANING–MANUAL mode.
• Select and injection volume LVL between 1 and 4
using the arrow keys and ,
LVL = 1 -> volume = 70 cm3
A few seconds after the setting is selected, the
pump starts to inject the selected volume. To
cancel injection, either before or during, simply
Nota Bene: if the pH-Clear option is not installed
with an EES, the cell must be removed from the
hydraulic circuit for descaling.
• PUNCTUAL OR PERIODIC REDUCTION OF THE PH BY THE PH-CLEAR PUMP
This function concerns EES Pro, and also EES if
the pH-Clear option is installed.
The pH-Clear pump may be set to inject acid
during
, either at periodic intervals, or one
single time:
LVL 0 1 2 3 4 5 6 7 8 9
duration
(hours) prior
to injection
No
injection
54 48 42 36 30 24 18 12 6
Reminder: the pH Clear pump is an integral part of EES Pro, and is available as an option for
EES.
The automatic electrode polarity switching system helps slow, and evenly distribute, deposition
Nevertheless, and even if the concentration of calcium dissolved in the water is within allowed
limits, here is a risk that this phenomenon will occur.
The scaling phenomenon may be counteracted by programming the injection of
set as follows:
•
• press the button to enter CELL CLEANING – AUTO mode
•
and according to the following table: