3350F Series Operation Manual 85
LDOFfv
Syntax [ PRESet] LDOFfv{SP}{ NR2}{NL}
[ PRESet] LDOFfv {NL}
PurposeSet and read the voltage of LOAD OFF
DescriptionThis command is for setting the Load voltage value of LOAD OFF.
CURR
HIGHLOW
Syntax[ PRESet] CCCURRHIGHLOW{SP}{ NR2}{NL}
[ PRESet] CCCURRHIGHLOW {NL}
Purpose Set and read the current of HIGHLOW
Description This command is for setting the required Load current. And this
command must be followed the next notices :
1. The required value of current must be included the number of the decimal
Point, otherwise the command will not be available.
2. The least significant number is the 5th behind the decimal point.
3. 3350F will set the maximum value of current of the Load automatically when
The value which has been set is over the maximum of the Load.
4. The value of LOW has to be smaller than HIGH.
5. The unit is A
CP
{HIGHLOW}
Syntax [ PRESet] CP{ HIGHLOW}{SP}{ NR2}{NL}
[ PRESet] CP{ HIGHLOW} {NL}
PurposeSet and read the value of Watt
DescriptionThis command is for setting the required value of Watt, and the unit is W
CRRES
{HIGHLOW}
Syntax [ PRESet] CRRES{ HIGHLOW}{SP}{ NR2}{NL}
[ PRESet] CRRES{ HIGHLOW} {NL}
PurposeSet and read the value of Resistance
DescriptionThis command is used for setting the required value of Load Resistance.
And this command must be followed the next notices:
1. The required value of resistance must be included the number of the decimal
Point, otherwise the command will not be available.
2. The least significant number is the 3rd behind the decimal point.
3. 3350F will set to the maximum value of the model automatically when the value
Of Resistance which has been set is over the specification of Load.
4. The Resistance value which has been set of LOW has to be smaller than HIGH.
5. The unit is Ω.
CV
{HIGHLOW}
Syntax [ PRESet] CV{ HIGHLOW}{SP}{ NR2}{NL}
[ PRESet] CV{ HIGHLOW} {NL}
PurposeSet and Read the value of Load Voltage
DescriptionThis command is used for setting the required Load Voltage. And this
command must be followed the next notices:
1. The required value of resistance must be included the number of the decimal
point, otherwise the command will not be available.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Prodigit 3350F Series and is the answer not in the manual?

Prodigit 3350F Series Specifications

General IconGeneral
BrandProdigit
Model3350F Series
CategoryPower Supply
LanguageEnglish

Related product manuals