86 PRODIGIT
2. The least significant number is the 5th behind the decimal point.
3. 3350F will set to the maximum value of the model automatically when the
value of Voltage which has been set is over the specification of Load.
4. The Voltage value which has been set of LOW has to be smaller than HIGH.
5. The unit is Voltage (V)
OCP: START
Syntax [PRESet] OCP:START {SP}{NR2}{NL}
[PRESet] OCP:START {NL}
PurposeSet and read the initial value of OCP test
DescriptionThis command is used for setting the required initial value (I-START) of
OCP test.
OCP: STEP
Syntax [PRESet] OCP:STEP {SP}{NR2}{NL}
[PRESet] OCP:STEP {NL}
PurposeSet and read the increasing value of OCP test
DescriptionThis command is used for setting the increasing value(I-STEP) of OCP
test
OCP: STOP
Syntax [PRESet] OCP:STOP {SP}{NR2}{NL}
[PRESet] OCP:STOP {NL}
PurposeSet and read the maximum value of OCP test
DescriptionThis command is used for setting the maximum value (I-STOP) of OCP
Test.
VTH
Syntax [PRESet] VTH {SP}{NR2}{NL}
[PRESet] VTH {NL}
PurposeSet and read the value of the Threshold Voltage
DescriptionThis command is used for setting the Threshold Voltage. That is the
OCP/OPP of this Load model when the output voltage of appliance is
lower or equaled to the VTH
OPP: START
Syntax [PRESet] OPP:START {SP}{NR2}{NL}
[PRESet] OPP:START {NL}
PurposeSet and read the initial value of OPP test
DescriptionThis command is used for setting the initial value (P-START) of OPP Test
OPP: STEP
Syntax [PRESet] OPP:STEP {SP}{NR2}{NL}
[PRESet] OPP:STEP {NL}
PurposeSet and read the increasing value of OPP test
DescriptionThis command is used for setting the increasing value (P-STEP) of OPP
Test