10.3 Combined OHMIC / Floating Head / collision system.
The best solution, which combines the advantages of both systems, is
to use the two solutions simultaneously. Then, when the OHMIC sensor
fails ( no contact on the soiled material ) the floating head sensor will
work.
In this case it is possible to use the anti-collision system instead of
the floating head ( in cases where OHMIC fails ) . It is sufficient to
combine the COLLISION signal with the MAT.DET.
10.4 Limitation of detection frequency
In the special functions, it is possible to set the area within which
detection will not be carried out in relation to the previous detection, i.e. if
you specify a distance of 100mm, after detection within a 100mm radius,
material will not be detected again and the system will assume that the
material is at the same level as in the previous detection.
*Planned transfer of functions higher ( beyond special functions )