Tab. 3: Input data
Slot Index Name Module name Data type Byte
count
Total:
Input data
Stop / Pause
(belongs to
the
‘Channel1/
Channel2’
module)
1 1
‘Channel 1’
Stop / Pause
channel 1
UINT8 1 Bit 7 = Stop
Bit 1 = Pause/
HOLD
Bit 0 = Pause
2 1
‘Channel 2’
Stop / Pause
channel 2
UINT8 1 Bit 7 = Stop
Bit 1 = Pause/
HOLD
Bit 0 = Pause
3 1
‘Channel 3’
Stop / Pause
channel 3
UINT8 1 Bit 7 = Stop
Bit 1 = Pause/
HOLD
Bit 0 = Pause
Controller
channel 1
‘controller
channel 1’
7 1 Configuration UINT16 2
Ä Chapter
1.7.5 ‘Settings
of the channel
configuration’
on page 19
(Parameter
via bus,
mode, limit
value direc‐
tion, control
time)
7 2 Limit value 1
value
FLOAT 4
7 3 Limit value 2
value
FLOAT 4
7 4 Setpoint 1 FLOAT 4
7 5 Xp FLOAT 4
Controller
channel 2
‘controller
channel 2’
Supplementary Instructions for PROFINET
®
11