P702 Calculation
Select the required calculation method, both will give similar answers, the
difference being the information required to complete the calculation. For
ratiometric it is normally sufficient to know the maximum flow at the
maximum head. Choose between:
1 = Absolute
2 = Ratiometric (Default)
P703 Minimum Head
This parameter is used to enter the distance, above empty, that represents
zero head and flow. This feature is used in Primary Measuring Devices
where the zero reference is at a higher level than the channel bottom, at the
point of measure. Enter distance in Measurement Units P104.
P704 Maximum Head
Enter the head value that represents maximum flow, enter in
Measurement Units P104.
Note any change to the value of this parameter will be reflected in P106
(Span) and vice versa.
P705 Maximum Flow
When P702 = 2 Ratiometric enter the flow rate value that occurs at
maximum head (P704), enter in volume units (P706) per time units
(P707).
When P702 = 1 Absolute, and all relevant flow parameters have been
entered, the maximum flow that occurs at maximum head P704 will be
calculated, after the unit is returned to RUN mode, and displayed in this
parameter in volume units (P706) per time units (P707).