EasyManua.ls Logo

Pulsar blackbox 130 - Parameter Record

Pulsar blackbox 130
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 83
Parameter Record
APPLICATION
Operation
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P100
Mode
1 = Dist.
P101
Xducer
2 = dB6
P102
Material
1=Level
Distances
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P104
Measurement Units
4 - feet
P105
Empty Level
19.685 feet
P106
Span
18.701 feet
P107
Near Blanking
0.984 feet
P108
Far Blanking
20.0%
Remote Alarm
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P985
Tel. No. 1
1 = Add 0
P986
Tel. No. 2
0
P987
Tel. No. 2
0
P988
Call Type
0 = Off
SMS Time
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P995
Interval
0.00 mins.
P996
SMS Start
00:00
P997
SMS Stop
23:59
P998
SMS Days
0

Table of Contents