Page #207 background image
Page 199
Filters
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P880
Gate Mode
0 = Fixed
P881
Fixed Distance
0.656 feet
P882
Process Filter
3 = Slow
P884
Peak Percent
50.0%
ECHO PROCESS
Xducer Status 1
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P900
Xducer 1 Status
Read Only
P901
Echo Confidence 1
Read Only
P902
Echo Strength 1
Read Only
P903
Average Noise 1
Read Only
P904
Peak Noise 1
Read Only
P905
Sensitivity 1
5.0dB
P906
Side Clearance 1
0.164 feet
SYSTEM
Passcode
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P921
Enable Code
1 = Yes
P922
Passcode
1997
Backup
Parameter Details
Entered Values
No.
Description
Default
1
2
3
4
5
P925
Parameter Backup
0 = No