Page 10
P024 Num Pings 1
Determines the number of times the transducer is “pinged” in each shot”, during
every processing cycle. In applications where there is a high level of noise or
attenuation due to dust or angles of repose, increasing the number of “pings” may
result in a larger “Average” trace and thereby increase echo processing reliability.
It should be noted that when increasing the number of “pings” processing times
will increase slightly and when reducing the number of “pings” per “shot”
slightly faster processing times will be obtained.
Options: Enter the Number of “pings” required to be taken during each
processing cycle.
Values: Min. 1
Max. 32
Default = 4