Page 16
P048 Gate Lock
This parameter should only be used under the direction of Pulsar. If ‘ON’ the gate
will remain ‘locked’ on the selected echo, regardless of the presence of any other
sized echo outside the gate, unless the selected echo falls below the value of the
loss limit.
Options 0 = No
1 = Yes
P049 Scale First
When P067 = 1 Best, this parameter determines the amount of weighting applied
to the first valid echo above the Loss Limits, before comparing it to other
competing echoes, the resulting largest echo will then be processed as the correct
echo.
Values Min = -100%
Max = 100%
Default = 0
Default = 40%