Data Log parameters
The data log parameters contain the following information:
Totaliser Audits
P460 to P479 Total Audits
When Pump Volume is enabled, parameters P460-P479 show the date and
pumped volume total for the last ten days, the first on the list are the most
recent and last ones are the oldest. When all ten total audits are full the
oldest is pushed out and all totals increment through to allow the new days
total to be registered in the first day’s total audit parameter allocation.
P480 Clear Logs
This parameter enables all the Total Audits (P460 P479) to be cleared to
factory default values.
Temperature
The following parameters give information on temperature conditions seen
by the Temperature source (P852) in ºC. All these parameters are read only
and cannot be changed, though if P852 is changed they will be reset.
P580 Minimum Temperature
This parameter displays the minimum temperature recorded.
P581 Minimum Temperature Date
This parameter displays the date when the minimum temperature was
recorded.
P582 Minimum Temperature Time
This parameter displays the time when the minimum temperature was
recorded.
P583 Maximum Temperature
This parameter displays the maximum temperature recorded.
Important Notice
To ensure the accuracy of Flow during a 24-hour period, ensure that the
Time P932 is set correctly. And if required, enable Daylight Saving for
the appropriate time difference P970 P979.