P812 Pump Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when a pump or general control
relay is switched on or off. The message is in the form “General 1 ON”, where
the number displayed is the number of the relay.
Pump messages will not be displayed
Pump messages will be displayed
P813 Control Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when a control relay is switched
on or off. The message is in the form “Time ON”.
Control messages will not be displayed
Control messages will be displayed
P814 Miscellaneous Messages
This parameter determines whether notification messages are displayed on
the auxiliary line of the display in run mode when a miscellaneous relay is
switched on or off. The message is in the form “Clock ON”.
Miscellaneous messages will not be displayed
Miscellaneous messages will be displayed
P815 Auxiliary Source
When P100 = 4 (Average) or 5 (Differential) the auxiliary display line can
be used to display the level on any of the two points of measurement.
Auxiliary display not used to display
measurement readings.
Displays level from optional Aux input.
Displays level from transducer 1