Enforcer: Programming Manual 
Page: 16 
3.8 Change Timers 
This function controls all timers of the Enforcer.  
Timers 
For a list of all timers, refer to Appendix C, on page 36.  
Most commonly used timers: 
Entry Time (0-255 seconds), Exit Time (0-255 seconds), Siren Time (2-15 minutes), Confirm 
Time (1-99 minutes), Wireless Supervision Time (0-99 hours), App Exit Time (0-199 
seconds) 
NOTE: The timer for inputs on 'Soak Control' is in the function 'ENGINEER TESTS'.  
Change Timers Programming  
1.  Press or to scroll to 'CHANGE TIMERS'. Press . 
2.  'A Entry Time' will be displayed. Enter the time and press . 
Refer to Appendix C, page 36 for all timers and enter the time 
on the required function and press  for the next timer.  
3.  Press to return to the Engineer menu. 
 
 
3.9 Codes And Users 
This function changes the Engineer code, the Master Manager code and adds/changes/deletes any 
Duress or Guard codes. 
Default Codes: User: None. Master Manager:2222. Engineer: 1111 
NOTE: User codes, fobs and keyfobs can only be changed in The Master Manager Menu. Please see 
the user manual for more information. 
5 Digit Pins? 
If enabled, all new codes added to the system will require a miniumum of 5 digits. 
PLEASE NOTE: Any existing 4 digit codes will still be valid. 
Delete Users And Fobs 
This will delete all the key fobs and user codes from the system. 
PLEASE NOTE: that this will not delete the Master Manager and the Engineer codes. 
Change Duress Codes 
[2] Duress Code: If the Enforcer is unset using a 'Duress' code, a silent 'Duress' or 'Hold Up' 
signal is sent.  
NOTE: ACPO policy prevents use of Duress codes for police call purposes. 
[3] Guard Code: A 'Guard code' can be used to unset the Enforcer only after an alarm has been 
activated for a minimum time (see 'Change Timer' Appendix C, page 36). The code will set a 
system and  an output type is available to signal when this code is used (0058 Guard Code). 
[4] Dial Out: A dial code is used to force the panel to dial out the UDL software while in ‘Day 
Mode’ 
Change Master Manager Code 
The Master Manager code can be 4, 5 or 6 digits long, or can be assigned to a tag. It may also 
have the following functions: 
[0] Unset / Set. [1] Unset Only. [2] Set Only. [3] None (used only to access the menu). 
Flexi Set: If enabled, the default area the device is assigned to, will set. If disabled, the default 
area will be shown on the display, and from here other areas can be selected. 
Wards/Access: This will only be displayed if an Entry Control or Access Control reader is 
installed on the system. If the address of the Entry Control or Access Control device is entered 
here, then the code will be assigned to that reader only. 
Change Engineer Code 
The Engineer code can be 4, 5 or 6 digits long. 
 
CHANGE TIMERS?
A Entry Time
 [030]