Enforcer: Programming Manual 
Page: 27 
Press  to view the power supply information for ZEMs, 
Output Modules, Keypads and readers. 
11. Press twice to exit. 
 
 
 
Diagnostics Programming: Communications. 
1.  Press or to scroll to 'DIAGNOSTICS'. Press . 
2.  Press  until ‘Communications: is displayed. Press . 
3.  See the ‘Modem and Communication Guide’ for more 
information. 
 
3.15 Engineer Reset Options 
The Engineer Reset Options are used so that once an alarm has occurred; the Enforcer system can 
only be reset by an engineer code or anti-code.  
Engineer Restore of Intruder 
If 'UK Intruder', an Engineer code must be used to reset the Enforcer after an alarm. 'Secure 
Intruder' should not be used. 
Engineer Restore of Hold Up 
If 'YES', an Engineer code must be used to reset the Enforcer after an Hold Up, Input Hold Up, or 
Duress activation. 
Engineer Restore of Tamper 
If 'YES', an Engineer code must be used to reset the Enforcer after a tamper activation. 
Engineer Restore of Soak 
If 'YES', an Engineer code must be used to reset the Enforcer after an input that is on 'soak' has 
triggered when the Enforcer is set. 
Engineer Restore of Confirmed 
If 'YES', an Engineer code must be used to reset the Enforcer after a confirmed alarm has 
occurred. 
Engineer Restore of Faults 
If 'YES', an Engineer code must be used to reset the Enforcer after the following faults: ATE 
telecom fail, Modem fail, ATE single path fail, Telecom line fail, Battery disconnect, Batt charge, 
Battery load, Excessive charge, Battery critical and Device fail. 
Anti-Code Restore 
If 'YES', the Enforcer will display an Anti-Code, to which can be used to generate a special reset 
code (usually from the ARC) to reset the Enforcer. 
NOTE: that if Anti-Code is selected, this will coincide with the options that have been selected 
previously. For example, if ‘Engineer Restore Intruder’ is selected, and Anti-Code is selected, 
then an anti-code will be produced on intruder activation. 
Engineer Reset Options Programming  
1.  Press or to scroll to 'SITE OPTIONS'. Press . 
2.  'Engineer Restore Intruder' will be displayed. Use [ or ] to 
enable/disable each option and press . Repeat for all 
functions. The engineer menu will be displayed once all 
functions have finished. 
 
 
 
 
 
 
 
 
00
View PSUs?
Communications?
ENGINEER RESTORE
OPTIONS?
Eng Restore Int
No           [0]