EasyManuals Logo
Home>Pyronix>Security System>ENFORCER Series

Pyronix ENFORCER Series User Manual

Pyronix ENFORCER Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Enforcer: Programming Manual
Page: 27
Press to view the power supply information for ZEMs,
Output Modules, Keypads and readers.
11. Press twice to exit.
Diagnostics Programming: Communications.
1. Press or to scroll to 'DIAGNOSTICS'. Press .
2. Press until ‘Communications: is displayed. Press .
3. See the ‘Modem and Communication Guide’ for more
information.
3.15 Engineer Reset Options
The Engineer Reset Options are used so that once an alarm has occurred; the Enforcer system can
only be reset by an engineer code or anti-code.
Engineer Restore of Intruder
If 'UK Intruder', an Engineer code must be used to reset the Enforcer after an alarm. 'Secure
Intruder' should not be used.
Engineer Restore of Hold Up
If 'YES', an Engineer code must be used to reset the Enforcer after an Hold Up, Input Hold Up, or
Duress activation.
Engineer Restore of Tamper
If 'YES', an Engineer code must be used to reset the Enforcer after a tamper activation.
Engineer Restore of Soak
If 'YES', an Engineer code must be used to reset the Enforcer after an input that is on 'soak' has
triggered when the Enforcer is set.
Engineer Restore of Confirmed
If 'YES', an Engineer code must be used to reset the Enforcer after a confirmed alarm has
occurred.
Engineer Restore of Faults
If 'YES', an Engineer code must be used to reset the Enforcer after the following faults: ATE
telecom fail, Modem fail, ATE single path fail, Telecom line fail, Battery disconnect, Batt charge,
Battery load, Excessive charge, Battery critical and Device fail.
Anti-Code Restore
If 'YES', the Enforcer will display an Anti-Code, to which can be used to generate a special reset
code (usually from the ARC) to reset the Enforcer.
NOTE: that if Anti-Code is selected, this will coincide with the options that have been selected
previously. For example, if ‘Engineer Restore Intruder’ is selected, and Anti-Code is selected,
then an anti-code will be produced on intruder activation.
Engineer Reset Options Programming
1. Press or to scroll to 'SITE OPTIONS'. Press .
2. 'Engineer Restore Intruder' will be displayed. Use [ or ] to
enable/disable each option and press . Repeat for all
functions. The engineer menu will be displayed once all
functions have finished.
00
View PSUs?
Communications?
ENGINEER RESTORE
OPTIONS?
Eng Restore Int
No [0]

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
BrandPyronix
ModelENFORCER Series
CategorySecurity System
LanguageEnglish

Related product manuals