Enforcer: Programming Manual
Page: 26
Diagnostics Programming: Wireless Devices.
1. Press or to scroll to 'DIAGNOSTICS'. Press .
2. 'Wireless Devices':. Press .
3. 'View Inputs’: To view each input status, press .
4. Use [ and ] to choose which inputs to view. Press .
5. The status of each input will be shown:
6. O=Open, C=Closed, T=Tamper, and F=Fault.
7. Press twice to exit, and again for the next sub-menu
item.
8. 'View Input Signal Strength’: To view each inputs signal
strength press .
9. Use [ and ] to choose which inputs to view. Press .
10. The status of each input will be shown:
3 = Excellent signal – Shows GREEN on the wireless Device
/ 80 to 100%.
2 = Good signal – Shows GREEN on the wireless Device /
between 30 to 80%.
1 = Weak signal – Shows RED on the wireless Device /
between 10 to 30%.
0 = Missing – Shows RED on the wireless Device / between
0 to 10%.
‘?’ = Waiting for device signal strength information.
11. Press twice to exit, and again for the next sub-menu
item.
12. Repeat the above for ‘View Bells Signal Strength’, and ‘View
Arming Station Signal Strength’.
13. 'View Inputs Battery Status':. Press .
14. Use [ and ] to choose which inputs to view. Press .
15. The status of each input will be shown:
Testing = Waiting for a Battery result
Good = At least one month of battery life remaining
Replace = Battery needs to be replaced immediately
16. Press twice to exit, and again for the next sub-menu
item.
17. Repeat the above for ‘View Bells Battery Status’, and ‘View
Arming Station Battery Status’
18. 'Wireless Dual Frequency Menu':. To view Dual Frequency
menu information. Press .
19. Press to exit.
Diagnostics Programming: Wired Devices.
1. Press or to scroll to 'DIAGNOSTICS'. Press .
2. Press until 'Wired Devices' is displayed:. Press .
3. 'View Inputs’: To view each input status, press .
4. ‘Endstation Inputs’: To view each input status on the I/O
board, press .
5. The status of each input will be shown:
6. O=Open, C=Closed, T=Tamper, and F=Fault. Press again
to view each input individually, and the resistor readings.
7. Press twice to exit, and again for the next sub-menu
item.
8. Repeat the above for ‘ZEM Inputs’.
9. ‘View PSUs’: To view the power supply information press .
10. ‘Endstation PSUs’: The voltage will be displayed. Press .
DIAGNOSTICS?
Wireless Devices
View Inputs?
Wrlss Inputs [2]
Endstation 1-32
OOCOC-----------
----------------
View Input
Signal Strength?
Wrlss Inputs [2]
Endstation 1-32
33333-----------
----------------
View Inputs
Battery Status?
Wrlss Inputs [2]
Endstation 1-32
Input [01]
Good
Wireless Dual
Frequency Menu?
DIAGNOSTICS?
Wired Devices
View Inputs?
Endstation
Inputs?

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals