Enforcer: Programming Manual
Page: 37
Timer Function Range
a supervision fault. This must be programmed to 2 hours or less for
compliance to EN50131.
Wireless
Jamming Time
This option is only applicable if wireless devices are installed. It is the
time window that if a wireless device had its signal ‘blocked’ a fault
would display. For example, if the time is set to 30 seconds, then if a
wireless device is ‘jammed’ longer than 30 seconds a fault will be
displayed. This must be programmed to 30 seconds or less (but not
zero) for compliance to EN50131.
0-100 seconds
Service Time This is a timer that can be set in days, and will display a message to
the user warning that a service is due. An engineer code will clear the
message.
367 days
Appendix D. Output Types
Type Active Restore
0000 Not Used (permanently off)
0001 Fire At alarm When a valid code is entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry and at
end of confirm time.
0004 Final Set All When system is FULLY armed At code entry to disarm
0005 Misoperation
When system is silenced after
any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
After two ‘intruder’ alarm
activations
At next code entry
0007 Tamper Any Any tamper alarm
At code entry to silence
And at end of confirm time.
0008 Duress Any
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any At alarm on a HU input only When a valid code is entered
0010 Gas At alarm When a valid code is entered
0011 Set Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry time
At code entry to unset
0013 Secure Intruder Any
At alarm, after exit time
started, until unset
At first valid code entry
and at end of confirm time.
0014 Siren Any When alarm live
When alarm silenced or when
siren timer expires
0016 Strobe Any When alarm live
When alarm silenced or when
strobe timer expires
0017 Omit Rearm Any
Input omitted if active (or in
alarm condition) at the end of
confirmation time.
When system disarmed
0018 Unconfirmed Any Any intruder or Tamper alarm At code entry to silence
0019 Can Set All
If all inputs and technical faults
in system are clear. Also once
entry time has started
If fault exists, and after final
arm
0020 Exit Starts All
At start of exit time to arm At code entry to disarm FIRST

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals