3.18 Software Revision
This option identifies all software revisions.
Software Revision Programming
1. Press or to scroll to 'SOFTWARE REVISION'. Press
.
2. The software revision will be displayed (e.g. V10.00c) Press
3. The Hub software revision will be displayed (e.g. V3.54).
Press
4. If any modems are connected, the display will show the
software revision here. Press
3.19 Clean Start
It is essential that a factory default (Clean Start) is performed after initial power up to ensure that
the correct defaults are applied. Please see page: 31 for a list of all defaults for each code.
Clear Wireless Data
If this function is not accepted, then all wireless inputs, wireless external sounders will be still
present on the Enforcer.
Clear Codes
If this function is not accepted, then all codes, tags and keyfobs will be still present on the
Enforcer.
Clear Logs
If this function is not accepted, then all event logs will be still present on the Enforcer.
NOTE: If everything is defaulted, the system memory will also be restored to factory defaults
except the following:
Keypad address '0' remains enabled at all times & the keypad in use remains enabled
Additional keypads connected will keep the area information
Clean Start Programming
1. Press or keys to scroll to 'CLEAN START'. Press
.Enter the default code 2000 for Ungraded defaults
2. 'CLEAR WIRELESS DATA' will be displayed. To delete all
wireless data (any inputs and bells that are learned)
press , or press to keep the wireless data.
3. 'CLEAR CODES' will be displayed. To delete/default all
user code, tag and keyfob data, press , or press
to keep the codes that are programmed.
4. 'CLEAR LOGS' will be displayed. To delete all event log
data press , or press to keep the event log data.
SOFTWARE
REVISION?
CLEAN START?
CLEAN START?
[ ]
Please Wait
Panel has been
clean started!
Cl’r Wirls Data?
Rev V10.00c
000121520Enforcer
Wireless HUB [1]
v3.54
V1.20 WiFi
Apps

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals