Enforcer: Programming Manual
Page: 25
Wired Devices?
View Inputs
This option views the status of all wired inputs: Open, Close, Tamper, and Fault.
Endstation Inputs: The status of the inputs will be shown. C = Closed. O = Open. F = Fault, T
= Tamper. The resistance reading can also be shown by pressing
for any of the above for
statuses.
ZEM Inputs: Choose the ZEM ID from [0] to [3] to view the input status.
View PSUs?
This option allows diagnostics of the power supply information for the PSU on the control panel,
as well as all the additional peripheral devices, such as ZEM or Output modules that have a PSU
on board.
Endstation PSU: End station voltage readings are displayed = Voltage: 13.7V.
ZEM PSUs: Choose the ZEM ID from [0] to [3] to read the PSU voltage readings.
OP Mod PSU: Choose the Output Module ID to read the PSU voltage readings.
Keypad Volts: Choose the Keypad ID from [1] to [3] to read the keypad voltage.
Reader Volts: Choose the Reader ID from [1] to [3] to read the reader voltage.
Communications
This function displays the information gathered from the communication device currently fitted.
GPRS Module:
GPRS Signal Strength: The range ‘0-31’ indicates the signal (31 = Excellent. >10 = Poor).
‘--.-- ‘ indicates no signal.
App or ARC Status messages: Displays the current connection status of the PyronixCloud.
Initialising – The panel is attempting to connect to the mobile network
No Network – There is no network available
Basic Network – The GSM network is available
Full Network – The panel is logged onto the GPRS network
Polling Cloud (App only) – The panel is polling the cloud
Polling ARC (ARC only) – The panel is polling the ARC
Last App Contact: Displays the time period since the last successful connection to the
HomeControl+ App.
Last Polled Cloud: Displays the time period since the last successful poll to the PyronixCloud.
Last Polled ARC: Displays the time since the last successful poll to the ARC.
LAN or WiFi Module:
(Wi-Fi Only) Signal Strength: The range ‘0-31’ indicates the signal
(31 = Excellent. >10 = Poor). ‘No Signal ‘ indicates no signal.
IP Address: Displays the IP address of the LAN Module (if installed).
Subnet Mask: Displays the Subnet Mask of the LAN Module (if installed).
Gateway: Displays the IP address of the Gateway.
App or ARC Status messages: Displays the current connection status of the PyronixCloud.
Initialising – The panel is attempting to connect to the network
No Network – There is no network available
Polling Cloud (App only) – The panel is polling the cloud
Polling ARC (ARC only) – The panel is polling the ARC
Last App Contact: The time period since the last successful connection to the HomeControl+
App.
Last Polled Cloud: The time period since the last successful poll to the PyronixCloud.
Last Polled ARC: The time since the last successful poll to the ARC.
PSTN and PSTN/VOICE Modem:
This will display the PSTN line status of whether there is a line present or missing.
GSM Modem
GSM Signal Strength: The range ‘0-31’ indicates the signal (31 = Excellent. >15 = Poor).
‘--.-- ‘ indicates no signal.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals