Enforcer: Programming Manual
Page: 23
Engineer Tests Programming: Soak Control
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press .
3. 'Walk Test' will be displayed. Press .
4. 'Soak Control' will be displayed. Press .
5. Select the inputs that are required to be soak tested. Each input
should be entered, following by . Press once finished.
6. 'Soak Days Left' will be displayed. Select the number of days
that the inputs will be left on soak test and press .
7. 'Initial Soak' will be displayed. Enter the number of days the
soak test will revert to in the event a soak input is triggered
during testing. Press .
8. Press to go back to the Engineer menu.
Engineer Tests Programming: Test Siren, Battery Load Test and
Test Outputs
1. Press or to scroll to 'ENGINEER TESTS'. Press .
2. 'Sound to play' will be displayed. Press
3. 'Walk Test' will be displayed. Press
4. 'Soak Test' will be displayed. Press
5. 'Test Siren' will be displayed. Press , any outputs
programmed as 'Siren Any' and 'Strobe Any' will trigger. Press
to exit.
6. 'Do Battery Load Test' will be displayed. Press to perform a
battery load test, the voltage will be displayed, followed by
'Battery Passed' if the test has been successful. Press .
7. 'Test Outputs' will be displayed. Press to perform a test on
any output type. For example if '0006' is entered, and the
key is pressed, a 'Confirmed Any' test will be activated. Press
to cancel the test.
8. Press to go back to the Engineer menu.
ENGINEER TESTS?
Sound to play
No Sound [00]
Soak Control?
Soak Inputs [--]
Soak Days Left
[00]
Initial Soak
[00]
ENGINEER TESTS?
Test Siren?
Testing Siren...
Do Battery Load
Test?
Testing Battery
13.3V
Test Outputs?
OP Test [0000]

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix ENFORCER Series and is the answer not in the manual?

Pyronix ENFORCER Series Specifications

General IconGeneral
Frequency868MHz
Operating Temperature-10°C to +40°C
User CodesUp to 50
Battery BackupYes, rechargeable battery
Remote ControlYes, via smartphone app and keyfob
UsersUp to 50
Mobile AppYes
Event LogYes, stores events
Siren OutputYes, built-in and external options
CompatibilityCompatible with Pyronix peripherals

Related product manuals