Enforcer: Programming Manual
Page: 42
DETECTION FAULTS
Fault Description Solution
Case Tamper
XXX
Case tamper switch open Secure switch closed. Same method of showing the
device as battery fault.
COMMUNICATION FAULTS
Fault Description Solution
Control
Panel
Modem Fault
End Station unable to
communicate with Digi
Modem
If modem not present, ensure that “Disable Digi” option
is set to ‘YES’ and “DOWNLOAD MODE” is set to ‘NONE’
or ‘RS232’. If present, but not detected, check the
modem is inserted correctly.
Control
Panel ARC
Call Fail
Call to ARC from Digi
Modem Digi Modem has
failed. Note: This is a
communication problem,
which is rarely caused by
an equipment fault.
Check ALL call details are programmed correctly.
Ensure signalling format is correctly set for ARC
receiver. Ensure that calls to the ARC or SMS bureaux
numbers are allowed on the PSTN line, eg 0800, 0845
etc.
Control
Panel Line
Fault 100
PSTN Line Fault signalled
by Digi Modem.
Only operative if "DOWNLOAD BY MODEM" selected OR
"DISABLE DIGI/SMS" is set to 'NO'
Note: 'Line Fault' timer operative.