ATA Bus Interface and ATA Commands
Quantum Fireball Plus AS 10.2/20.5/30.0/40.0/60.0 GB AT 6-55
6.7.16
6.7.166.7.16
6.7.16 IDLE IMMEDIATE
IDLE IMMEDIATEIDLE IMMEDIATE
IDLE IMMEDIATE
COMMAND CODE – E1h
DESCRIPTION – The IDLE IMMEDIATE command immediately puts the drive in
the IDLE mode.
INPUTS
OUTPUTS
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Features na
Sector Count na
Sector Number na
Cylinder Low na
Cylinder High na
Device/ Head obs na obs DEV na
Command E1h
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Error nananananaABRTnana
Sector Count na
Sector Number na
Cylinder Low na
Cylinder High na
Device/ Head obsnaobsDEVnananana
Status BSY DRDY DF na DRQ na na ERR