COMMAND CODE – E6h
DESCRIPTION – The Quantum Quantum Fireball Plus AS hard disk drives
considers the SLEEP Mode to be equivalent to the STANDBY mode, except that a
hardware reset or a software reset is required before issuing any command to the
drive.
INPUTS
OUTPUTS
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Features na
Sector Count na
Sector Number na
Cylinder Low na
Cylinder High na
Device/ Head obs na obs DEV na
Command E6h
Register
RegisterRegister
Register 7
77
76
66
65
55
54
44
43
33
32
22
21
11
10
00
0
Error nananananaABRTnana
Sector Count na
Sector Number na
Cylinder Low na
Cylinder High na
Device/ Head obsnaobsDEVnananana
Status BSY DRDY DF na DRQ na na ERR