“Read From Device”: It is used to read all configuration from device which connects to PC. 
“Load Configuration From File”: It is used to load configuration file to the manage tool. 
 
[Send All Configuration]: It is used to execute all configurations in Command Operation Space 
except GTRTO. 
 
[Save All Configuration]: It is used to save all configurations in Command Operation Space to 
file.
 
 
[Connect/Disconnect to COM]: It is used to Connect/Disconnect to COM manually. 
 
2.4.4 Status Bar 
 
 
There is system status and current status in status bar. 
 
[System Status]: It indicates the count of commands which are waiting and executing to set. 
 
[Current Status]: It indicates current COM status, IMEI, protocol version and software version 
which read from device. 
 
2.4.5 Command Browser and Command Operation Space 
This area is mainly read and set parameters of device   
 
2.4.5.1 Command Brower 
Command Brower separates  all @track protocol command to several parts. Click Function in 
command Brower, reference parameters of this command will be shown in command operation 
space. 
 
Command Brower  Function Description  Relative Command 
Server Connection 
Bearer Setting Information  GTBSI 
Backend Server Register Information  GTSRI 
Quick Start Settings  GTQSS 
Device Configuration 
Global Configuration  GTCFG 
Auto-Unlock PIN  GTPIN 
Software Protocol Watchdog  GTDOG