• To edit the text, using the [roller] or [dial], press the buon, scroll to select the desired leer, then press the
buon again to move to the next space. To toggle between lower and upper case, long-press the buon.
Press the [RTN] buon to exit out of text eding mode.
Image - Image displayed on the main view (only for radios with 212 x 64 displays).
Image dimensions shall be 64 x 32 pixels, 16 bit, grayscale, .bmp le. The image must be stored in the IMAGES folder
of the SD card.
Timers
Timer 1/2/3 - There are 3 congurable mers in EdgeTX. The following conguraon opons will be displayed once
the mer is no longer set to OFF:
Timer 1 [Mode] [Switch]
[Mode]: The opons include:
• OFF- The mer is not used
• ON - The mer runs all the me
• Strt (Start) -The mer starts once the congured switch is acvated. Aer the me is started, the mer
ignores the switch posion.
• THs (Throle) - The mer starts once the throle is raised and the congured switch is acvated. The mer
will stop counng if either the throle posion is lowered back to the minimum value or the congured
switch is deacvated.
• TH% (Throle %) - The mer counts proporonally to the throle. It counts in real-me at full throle and
half speed at 50% throle.
• THt (Throle Start) - The mer starts once the throle is raised and the congured switch is acvated. Aer
starng, the mer ignores the throle posion and will keep counng unless the switch is deacvated.
[Switch]- Select the switch that will trigger the mer to start. If no switch is selected, the mer will trigger based only
on the congured mode. In addion to a switch, you can also select a trim, a telemetry source (triggered when
telemetry data is received from that source), or physical acvity (sck movement or buon press) (labelled as ACT)
Those items with a "!" mark in front of the trigger name mean that the condion is reversed. For example, "!SA-"
means "when SA switch is not in middle/centre posion (= up or down)".
Name: Name of the mer
Start- The me used for the mer's advanced funcons. The default value is 00:00 and when le as such, the mer
operates like a stopwatch, counng upward unl stopped. If a dierent me is entered in this box, then the
addional eld will appear next to the me with the opons: Remain or Elaps.
If set to Remain, the counter will funcon like a countdown mer - counng down from the designated me to zero
and then alerng the user. If set to Elaps, the mer funcons like an alarm, counng up from zero unl the
designated me and then alerng the user.
Persist (Persistence):
• O - The mer value is reset when switching models or when the radio is turned o / on.
• Flight - The mer value is NOT reset when switching models or when the radio is turned o / on. The mer
value is only reset when the Reset ight opon is selected in the Reset menu.
• Manual Reset - The mer value is reset only when it is individually selected to be reset (example: Reset
mer1) in the Reset menu.