EasyManua.ls Logo

Ransomes HM600 - Page 79

Ransomes HM600
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en-79
MAINTENANCE AND LUBRICATION 8
Interval Item Section
Every 2 Years
Replace oil separator related rubber piping.
Replace DPF related rubber piping.
Replace intake air line and suction air pressure
takeout rubber piping.
Replace boost sensor pressure rubber piping.
Replace EGR cooler rubber piping.
Replace water rubber piping.
Replace lubricant rubber piping.
Change radiator coolant.
Replace radiator hoses and clamp bands.
Replace fuel pipes and clamp bands.
Replace intake air line.
Replace fan belt (or every 500 hours).
*3
*3
*3
*3
*3
*3
*3
-
*3
*3
*3
*3
The jobs indicated by must be done after the first 50 hours of operation.
*3 Consult your local Kubota dealer for this service.
The items listed above (@ marked) are registered as emission related critical parts by
Kubota in the U.S.EPA non road emission regulation. As the engine owner you are
responsible for the performance of the required maintenance on the engine according to
the above instruction. Please see Warranty Statement for detail.
The items listed above other than @ marked items are not necessary to keep the
emission-related warranty valid.
Failure to perform the maintenance will cause problems that will significantly degrade.
IMPORTANT
Refer to engine manufacturers manual for the complete engine maintenance procedures.
8.6
8.4
8.8
8.12
8.5
8.4
B
A
8.11

Table of Contents