Service Manual Rayjet
Laser Safety
Safety information
07/09/2010 Trotec Produktions- und Vertriebs GmbH_Linzer Strasse 156, A-4600 Wels, Austria, Technical Support 9 / 53
tel_+43 (0)7242 239-7000, fax_+43 (0)7242 239-7380, mailto: rayjet@troteclaser.com www.rayjetlaser.com
2.2.1 Safety Interlock System
Your Rayjet is equipped with an integrated safety interlock system which cuts off the power of the
laser tube immediately as soon as one of the interlocked doors/panels is opened.
CAUTION
Do not attempt to alter the interlock system as that could result in hazardous radiation
exposure.
CAUTION
Technicians who are performing service procedures must be trained in laser safety,
and if they are defeating interlocks, they must wear laser protective eyewear designed
for the 10,6μm CO
2
laser energy.
The top door and the maintenance panel on the right side, are interlocked. If the interlocks are
defeated access to laser class IV radiation is possible through any of these doors.
CAUTION
When a non interlocked cover is opened (and the machine is powered) access to
class IV laser radiation is possible.
These covers are labeled with „DANGER: INVISIBLE LASER RADIATION WHEN
OPEN. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED
RADIATION“
Top lid interlocks
Maintenance
panel
interlocks