If the sensor learning has not
yet taken place, the status mes-
sage No running parameter is
displayed.
It is possible either to learn an
individual sensor or all sensors
together.
RAD: Learning the door move-
ments.
AIR: Learning the background.
During the closing cycle the radar sen-
sor is learning the door leave move-
ments. Movements in the radar field dur-
ing the sensor learning disturb the
measuring and shall be prevented.
The sensor learning must be repeated, if
settings of the sensor or of the door
have been modified or if people moved
in the detection field during the learning.
Activate door leaf learning and leave
sensing field. The learning is completed
when the LED stops flashing.
Recommendation: Activate sensor
learning only if door leaf masking has
been enabled.
Changes on the AIR sensor don’t re-
quire any repetition of this sensor
learning.