Mosaic fieldbus modules
8540801 • 01/02/2017 • Rev.15 7
Whenever Mosaic System employs as Input a Selector (-> Functional Block: MOD-SEL), the
datum sent from: Master M1 -> Bus module -> FieldBus is the following:
DATUM SENT
1
2
4
8
All status occupy 4 bits: 0 to 3 or 4 to 7 in the "State Inputs" Footprint in the Output.
The content of the bits is given below.
Channel 1
Channel 0
OVERSPEED/
WINDOW
7
6
5
4
3
2
1
0
1 -> under
0 -> over
DIRECTION
1 -> CCW
0 -> CW
STANDSTILL
1 -> Blocked
0 -> Moving
0 Permanent
OVERSPEED/WINDOW
1 -> under
0 -> over
DIRECTION
1 -> CCW
0 -> CW
STANDSTILL
1 -> Blocked
0 -> Moving
0 Permanent