45
Service
parameters:
(according
to Recom)
Description
Adjustment range
Factory
setting
System
boiler
Factory
setting
Combi
boiler
4/5
Flow temperature
set point during
forced part load
20 - 90 °C
60 60
6/6-7
Fan speed at full load
(HTG) D.N.C.
1000 - 6000 rpm
3900 3900
7/10-11
Fan speed at part load
(HTG and DHW) D.N.C.
1000 - 6000 rpm
2300 2300
8/12
Modulation start point
F/R, dt °C D.N.C.
5 - 30 °C
25 25
b/13
Switch on differential
(DHW) D.N.C.
1 - 20 °C
5 1
c/8-9
Fan speed at full load
(DHW) D.N.C.
1000 - 6000 rpm
5450 5450
G/14
Forced part load time
after start (HTG)
3 - 10 minutes 3 3
H/15
Fan speed at start
D.N.C.
1000 - 6000 rpm 2500 2500
J/17 DHW control mode 0 / 1 0 0
L/18
Pump setting in
heating mode
0 / 1
1 = high
0 = low
(manual adjustable)
11
L/18
Pump setting during cir-
culation
0 / 1 0 0
n/19
HTG cut in Dt (based on
return) D.N.C.
0 - 20 3 3
o/20 Pre heat period 0 -10 hours 0 0
P/21 Boiler type
0: not used
1: Combi
2: System
21
U/38
Max. shut down time
during continuous
heat demand
0 -30: minutes 15 15
51/32
Hysteresis before ending
DHW D.N.C.
1 - 30 °C
88
11/16
Differention end
DHW-demand D.N.C.
-5 - 15 °C
00