2.4.2 Specic information
Only cold water of drinking water quality may be used to supply the system.
When supplying with softened water, only use lters for drinking water with > 4° dH total hard-
ness.
Store components in a dry location.
The system must not come into contact with chemicals, solvents, or any fumes.
Before the lter system is put into operation, the consumer unit supplied must be free from limes-
cale.
No copper pipes or galvanized / nickel-plated pipes or connecting parts may be installed between
the lter system and the consumer unit.
The lter cartridge must not be opened or mechanically damaged.
Water that is already microbiologically contaminated or of unknown microbiological quality may
not be used under any circumstances without su󰀩cient disinfection before or after the lter.
The lter head and the wall bracket must be replaced after 5 years of use / at the latest 6 years
after the production date. This also applies to hoses and seals. Pay attention to the date of the
production stamp.
All components must be installed in accordance with country-specic guidelines. DIN 1988 must
be observed for the assembly and operation of the system.
If the system pressure is greater than 8 bar, a pressure reducer must be installed upstream of the
lter system.
The sensor unit must not be exposed to any mechanical loads. Pay particular attention to the
lever e󰀨ect of hoses and bend radii. If necessary, provide support for supply lines!
Only use commercially available AA batteries (2 x) for the sensor unit.
Ensure that the battery cover of the sensor unit is properly closed. Otherwise, foreign objects or
moisture could penetrate.
2.5 Authorized persons
Installationandmaintenanceoftheltersystemsmayonlybecarriedoutbytrainedandauthorizedper-
sonnel�
Operation and maintenance of the equipment may only be performed by trained personnel�
Anyrepairsnotdescribedintheseoperatinginstructionsmayonlybeperformedbyaqualiedelectrician.
2.6 Disclaimer
Renfert GmbH shall be absolved from all claims for damages or warranty if:
The product is employed for any purposes other than those specied in the operating instruc-
tions.
The product is altered in any way other than those alterations described in the operating instruc-
tions.
The product is not repaired by an authorized dealer or if original Renfert spare parts are not used.
The product continues to be used despite obvious safety defects or damage.
The product is subjected to mechanical impact or is dropped.
The product is installed incorrectly or not used as specied in the operating instructions.
3 General description
With the POWER steamer water softener, the carbonate hardness of the water for the POWER steamer 2
isreducedintheowprocessusingion-selectiveltermedia.Thereductionofhardnesscanbeadapted
tothequalityofthelocaldrinkingwaterviatheblendingunitinthelterhead.
Inaddition,theltermaterialbindsheavymetalionssuchascopperandcadmium.
Theintegratedactivatedcarbonblockreducesunwantedturbidity,organicimpurities,aromas,andavor-
ingsaswellaschlorineresidueintheltrateandintheblendedwater.