OMP40-2 installation guide
3.4
System
installation
Positioning the OMM-2C receiver with OSI or OSI-D interface
WARNING: Ensure the machine tool is in a safe condition and power is removed before removing
covers. Only qualied persons should adjust switches.
The OMM-2C receiver with OSI or OSI-D interface should be mounted as near to the machine spindle
as possible.
When mounting the OMM-2C receiver, it is important that the sealing ring forms a tight seal around the
rim of the bore into which the body of the OMM-2C receiver is to be located.
Performance envelope when using the OMP40-2 with a OMM-2C receiver with OSI or OSI-D interface
(modulated transmission).
The diodes of the OMP40-2 and the OMM-2C receiver with OSI or OSI-D interface must be in each
other’s field of view and within the performance envelope shown. The OMP40-2 performance envelope
is based on the optical centre line of the OMM-2C receiver with OSI or OSI-D interface being at 0° and
vice versa.
OMP40-2
75°
60°
45°
30°
15°
15°
30°
45°
60°
75°
75°
60°
45°
30°
15°
15°
30°
45°
60°
OMM-2C
75°
Optical centre line
2.5 (8.2)
2.0 (6.5)
1.5 (4.9)
1.0 (3.3)
0.5 (1.6)
2.5 (8.2)
2.0 (6.5)
1.5 (4.9)
1.0 (3.3)
0.5 (1.6)
Typical plot at 20 °C (+68 °F) 360° transmission around probe axis in m (ft)
Switch-on / switch-off
Operating – standard power mode
Operating – low power mode
Operating – ultra low power mode

Table of Contents

Other manuals for Renishaw OMP40-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renishaw OMP40-2 and is the answer not in the manual?

Renishaw OMP40-2 Specifications

General IconGeneral
BrandRenishaw
ModelOMP40-2
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals