2.3
OMP40-2 basics
OMP40-2 switch-on method OMP40-2 switch-off method
Switch-off options are configurable
Switch-on time
Optical on
Optical switch-on is
commanded by machine
input.
Optical off
Optical switch-off is commanded by
machine input. A timer automatically
switches the probe off 90minutes
after the last trigger if it is not
switched off by machine input.
Legacy (start filter off):
0.3 seconds
Legacy (start filter on):
0.8seconds
Modulated: 0.3 seconds
Optical on
Optical switch-on is
commanded by machine input
or auto start.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
NOTE: Issuing a further M code
during the timeout period will also
reset the timer.
Configurable settings
Switch-off methods
The following switch-off options are user-configurable.
1. Optical on / Optical off
2. Optical on / Timer off