EasyManuals Logo

Renishaw OMP40-2 User Manual

Renishaw OMP40-2
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
7.1
OMP40-2LS system
Introduction
The OMP40-2LS probe has a reduced switch-on range when compared to an OMP40-2 probe.
Performance envelope with an OMM-2 receiver with OSI or OSI-D interface or
OMI-2 / OMI-2T / OMI-2H interface / receiver
Typical plot at 20 °C 360° transmission around probe axis in m
OMP40-2LS
OMM-2
OMI-2T
OMI-2H
OMI-2
60°
45°
45°
15°
30°
30°
15°
60°
60°
45°
45°
15°
30°
30°
15°
60°
75°
4 (13.1)
3 (9.8)
2 (6.5)
5 (16.4)
4 (13.1)
3 (9.8)
2 (6.5)
1
(3.3)
5 (16.4)
75°
75°
75°
Optical centre line
1 (3.3)
Switch-on / switch-off
Operating – standard power mode
Operating – low power mode
Operating – ultra low power mode

Table of Contents

Other manuals for Renishaw OMP40-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renishaw OMP40-2 and is the answer not in the manual?

Renishaw OMP40-2 Specifications

General IconGeneral
BrandRenishaw
ModelOMP40-2
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals