SC No. Level Error Name/Error Condition/Major Cause/Solution
SC531-00 D
Development Cooling fan error
The fan motor lock (rotating state) signal is sampled at 100 ms intervals
and t the machine fails to receive the lock signal 50 times in succession.
Failed fan motor
Disconnected connector
Harness disconnection
Defective IOB
Replace the fan motor.
Check the connector.
Replace the harness.
Replace the IOB.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC541-00 A
Broken fusing (Center) thermistor wire
The condition whereby the temperature is -20 deg C or less for 5 seconds
has been detected 10 times or more.
Broken thermistor wire
Bad connector contact
Clear the SP: fusing SC.
Check the connector connection.
Replace the fusing (Center) thermistor.