Main SP Tables-2
SP2-XXX (Drum)
2001 [C biasControl]
2-001-001 C setting E
[-1350 to -900 / -1020 / 1V/step]
C: bias value.
This setting is available when the bias
control is Off.
2-001-002 C(low) setting E
[-400 to -200 / -350 / 50V/step]
C(low): The value of C(low) output.
2-001-011 Vd_ref_lowhumi E
[-700 to -400 / -420 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, low humidity.
This setting is available when the bias
control is On.
2-001-012 Vd_ref_midhumi E
[-700 to -400 / -470 / 10V/step]
Displays or adjusts the target dark potential
(Vd) in the Env Division, mid humidity.
This setting is available when the bias
control is On.
2-001-013 Vd_ref_highhumi E
[-700 to -400 / -490 / 10V/step]
Displays and adjusts the target dark potential
(Vd) in the Env Division, high humidity.
This setting is available when the bias
control is On.