SC600 (Device Communication)
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC641-00 D
Communication error: Engine (Timeout error)
Communication error: Engine (Retry error)
There is no response from the engine even after the timeout period
specified during the communication has elapsed.
The communication has failed when sending the normal mode
(ESIF_LECI_NORMAL) command even after exceeding the
maximum number of command transmission retry.
Controller board/software defective
The connection between the controller board and engine board is
faulty.
Engine board/software defective
Check the connection between the controller board and engine
board.
Turn the main power off/on.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC653-00 D
Incorrect remote service ID2
If the serial number*1 for producing ID2*2 has any of the following
problems:
Blank
Contains control characters
Cannot be read
*1: The serial number refers to "MachineSerial Set" (SP5-811-001).
*2: ID2 refers to "Machine No. Setting" (SP5-811-003).
The serial number was not specified at the factory.
The NV memory is corrupted and cannot be read.
The NV memory has been corrupted while writing data into it.
Turn the main power off/on.
If the problem persists, the hardware is faulty.