SC No. Level Error Name/Error Condition/Major Cause/Solution
SC900-00 D
Electronic counter error
The value provided by the electronic total counter is outside the normal
range.
Unexpected NVRAM installed
Defective NVRAM
NVRAM data corruption
Data is stored in an unexpected area due to external causes.
The count requests made by SRM upon receiving the PRT have not
yet been processed.
Install an NVRAM device designed specifically for the model.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC920-** B
Printer application error
A serious application error that stops the machine from operating is
detected.
920-00
At PM startup, no response was returned within the specified period
of time.
920-01
A time-out occurred during PM operation.
920-02
WORK memory acquisition failed.
920-03
The filter process cannot be started.
920-04
The filter process was aborted.
Turn the main power switch off and on.