EasyManua.ls Logo

Ricoh Aficio MP171 - SC990-00 Software performance error; SC991-00 Software continuity error; SC992-00 Undefined SC error

Ricoh Aficio MP171
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC990-00 D
Software performance error
The software attempted to make an unexpected operation.
Incorrect argument
Incorrect internal parameter
Insufficient working memory
Abnormal performance caused by an error that cannot be detected
in normal SC detection due to hardware specifications.
Turn the main power switch off and on.
Reinstall the software of the controller board.
Reinstall the software of the engine board.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC991-00 C
Software continuity error
The software has attempted to perform an unexpected operation.
(However, the process can continue running if recovery processing is
carried out.)
Incorrect argument
Incorrect internal parameter
Insufficient working memory
May have resulted from an error that cannot be detected by the
hardware using normal SC detection.
Not required
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC992-00 D
Undefined SC error
An error that is not controlled by the system occurred (the error does not
come under any other SC code).
A SC code used in the previous machine was applied erroneously.
Turn the main power switch off and on.
Service Call
143

Table of Contents