Main SP Tables-5
SP5-XXX (Mode)
5024
[mm/inch Selection]
Selects whether mm or inches are used in the display.
Note: After selecting the number, you must turn the main power switch off and on.
5-024-001 0:mm 1:inch C
[0 or 1 / 1 / 1/step]
0: mm (Europe/Asia)
1: inch (USA)
5045
[Accounting counter]
Selects whether the accounting counter is displayed on the LCD or not.
SP5-801-001/003 will not clear this SP. The value will be under an exclusive control
because the value varies in segments.
5-045-001 Counter Method C
[0 or 1 / 0 / 1/step ]
0: Pattern 1
1: Pattern 2
5051
[Refill Toner Disp]
Enables or disables the toner refill detection display.
5-051-001 - C
[0 or 1 / 0 / 1/step]
0: On
1: Off
5055
[Display IP Address]
Display or does not display the IP address on the operation panel.
5-055-001 - C
[0 or 1 / 0 / 1/step]
0: Off
1: On
Main SP Tables-5