SC No. Level Error Name/Error Condition/Major Cause/Solution
[0F31]
Engine I/F: ASIC register error
The /CONFIG_DONE signal is not detected even after the specified time
has elapsed after turning the power on or restoring from energy saver
mode.
Downloading of the Config data to FPGA has failed.
Replace the controller board.
[0F10]
Fsync input timeout
After the /PRREQ signal is detected, the /FSYNC(/FGATE) signal of the
first color is not detected even after the specified time has elapsed.
Connector, harness defective
FGATE control error
EGB defective
-
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC850-00 B
Network I/F error
The access to the network work is unavailable due to an error in the
printer driver.
-
-
Service Call