2-961-002 Level 2 E [0 to 1 / 0 /1 / step]
2990
[Duty Control]
Correction values of printing interval control in order to avoid the increasing
temperature from continuous printing.
2-990-001 Counter E [0 to 65535 / 0 /1count / step]
2-990-002 Lower E [2000 to 60000 / 14400 /1count / step]
2-990-003 Upper E [2000 to 60000 / 158400 /1count / step]
2-990-004 OFF/ON E [0 to 1 / 0 /1 / step]
2-990-005 Accumulation E [0 to 65535 / 0 /1count / step]
2997 [PCDU STOP]
2-997-001 End Mgn Distance E
[100000 to 960000000 / 10490000 /
10000mm/ step]
The parameter which is used to calculate the
print stop end threshold [mm]. "Print stop end
threshold [mm]" = "End threshold (distance)
[mm]" + "End margin (distance) [mm]"
* "+1 [kp]" = "+650000 [mm]" (Add
approximately 650000 [mm] to increase the
end distance by 1 [kp])
2998 [Timing Control]
2-998-001 T:ReverseRotation E
[1 to 100 / 32 / 1msec/step]
Adjusts the reverse rotation time of PCU
reverse rotation.
2-998-002 T:MotorStop E
[550 to 1000 / 550 / 50msec/step]
Adjusts the stop rotation time of PCU reverse
rotation.
2-998-003 T:NormalRotation E
[1 to 100 / 29 / 1msec/step]
Adjusts the normal rotation time of PCU
reverse rotation.