System Service Mode
SM Appendix 3-7 D127/D128
Appendix:
SP Mode
Tables
1159* Fusing Jam Detection
1159 1
SC Display [0 = No / 1 = Yes]
Enables or disables consecutive jam detection at the fusing unit. If this SP is
set to "1" (default: 0), consecutive fusing jam alarm occurs (SC559) when the
machine detects three consecutive paper jams at the fusing unit.
1902 Frequency
1902 1
Displays the fusing lamp power control frequency (as detected by the zero
cross signal generator).
1907 Paper Pre Feed Timing
1907 20 F2 Tray
[-10 to 10 / 0 / 1 mm/step]
The larger value set, the larger area of the
paper is pre-fed for each tray.
1907 21 F3 Tray
1907 22 F2 Tray
1907 23 F3 Tray
1950 Fan Cooling Time Set
1950 1
Fusing Exit Fan [0 to 900 / 10 / 1 sec/step]
Sets the duration of the fusing exit fun on waiting and abnormal condition.
1951 Fan start Time Set
1951 1
Fusing Exit Fan [0 to 900 / 60 / 1 sec/step]
Sets the time before fan operates at startup.
1952 Fan Control Off Mode Time Set
1952 1
Fusing Exit Fan [0 to 60 / 10 / 1 min/step]
Sets the time before fan operates at startup from sleep mode.