1.SC Codes
97
Error Name/Error Condition/Major Cause/Solution
Malfunction due to an abnormal increase of the torque (caused by, for
example, overload due to remaining paper)
1. Check for remaining paper.
2. Perform an Output check for corresponding device.
3. Reconnect the connector.
4. Replace the Exit Path Entrance Motor.
5. Replace the drive unit.
6. Replace the PFB.
7. Replace the harness between PFB and Exit Path Entrance Motor.
Error Name/Error Condition/Major Cause/Solution
Grip Motor 1 (Tray 1) Rotation Error
Grip Motor 2 (Tray 2) Rotation Error
2 seconds after motor startup, the motor lock error signal (LOCK signal) was
detected for 1200 msec or more.
Harness broken
Connector disconnect
Replace the Grip Motor.
Reconnect the connector.
Error Name/Error Condition/Major Cause/Solution
Buffer Pass Unit: Cooling Fan Alarm 1
Buffer Pass Unit: Cooling Fan Alarm 2
Buffer Pass Unit: Cooling Fan Alarm 3
Buffer Pass Unit: Cooling Fan Alarm 4
Buffer Pass Unit: Exhaust Fan Alarm 1
Buffer Pass Unit: Exhaust Fan Alarm 2
Buffer Pass Unit: Exhaust Fan Alarm 3