1.SC Codes
313
Error Name/Error Condition/Major Cause/Solution
Reconnect the connector.
Replace the signature exit roller motor.
Replace the trim unit entrance sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Main grip late error
There was no stack received from the sub grip unit; the main grip signature
sensor detected no stack.
Signature jam occurred in the sub grip unit.
Signature move motor defective
Main grip signature sensor defective
Connector loose, broken, defective
Slave control board defective
Reconnect the connector.
Replace the signature move motor.
Replace the main grip signature sensor.
Replace the slave control board.
Replace the motor harness.
Replace the sensor harness.
Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power
off/on.
Error Name/Error Condition/Major Cause/Solution
Perfect Binder: Trim unit entrance sensor lag error
At the end of initialization at power on, the entrance path sensor went ON.
Signature jam occurred in the trim unit.
Trim unit entrance sensor defective
Connector loose, broken, defective
Cutter control board defective
Reconnect the connector.