DG1000 Command System RIGOL
Programming Guide for DG1000
Detailed information of each command:
1.
BURSt:MODE
Syntax BURSt:MODE {TRIGgered|GATed}
Function Set the burst mode to trigger (TRIGgered) or gated (GATed).
Explanations In trigger mode, the generator outputs a wave with specified
number of cycles once it receives a trigger from the specified
trigger source (via sending TRIGger:SOURce).
In gated mode, the output state of waves (“ON” or “OFF”)
depends on the external signal level at the [Ext
Trig/FSK/Burst] connector on the rear panel.
The default burst mode is trigger.
Example BURS:MODE GAT
2.
BURSt:MODE?
Syntax BURSt:MODE?
Function
Query the burst mode.
Return Value The query returns TRIG or GAT.
Syntax
BURSt:NCYCles {<cycle>|INFinity|MINimum|MAXimum}
Function
Set the cycle number of burst (only used in triggermode).
Explanations <cycle> is the cycle number set by users.
MIN=1, MAX=50,000, INF is infinite.
Example
BURS:NCYC 100
4.
BURSt:NCYCles?
Syntax BURSt:NCYCles?
Function Query the cycle number of burst.
Return Value The query returns the burst counting in scientific notation (such
as 1.000000e+02) or returns “Infinite”.
5.
BURSt:INTernal:PERiod
Syntax BURSt:INTernal:PERiod {<second>|MINimum|MAXimum}
Function Set the period of burst in internal trigger mode.
Explanations <second> is the burst period set by users, the default unit is
s.