81
Compact Flash Card
2.1 File type
00: Not used
01: Standard memory (manual store)
02: Standard memory (timer measurement)
03: Transient store
05: Direct card write file
2.2 Measurement parameters
[Common settings for vibration meter and analyzer]
Measurement data type
Measurement data type 0: Acceleration, 1: Velocity, 2: Displacement,
3: Envelope
Acceleration unit 0: m/s
2
, 1: G
Velocity unit 0: mm/s, 1: inch/s
Displacement unit 0: mm, 1: mils
Analysis mode 0: Vibration meter, 1: Spectrum, 2: Time wave-
form
Input range 0: minimum to, 5: maximum
Pickup sensitivity mV/ms
-2
(numeral, multiplication factor)
Numeral ∗∗∗: 100 to 999
Multiplication factor 100: 0.1, 010: 0.01, 001: 0.001
High-pass filter 0: 3 Hz, 1: 10 Hz, 2: 1 kHz
Low-pass filter 0: 1 kHz, 1: 5 kHz, 2: 20 kHz
Timer store 0: OFF, 1: ON
Time HH:MM in 24-hour notation
Store interval MM in minutes (2 digits)
Store count ∗∗∗: 001 to 500