Do you have a question about the Rion VM-83 and is the answer not in the manual?
| Brand | Rion |
|---|---|
| Model | VM-83 |
| Category | Measuring Instruments |
| Language | English |
Details the various buttons, connectors, and indicators on the front panel of the VM-83 unit.
Details the connectors and ports located on the rear panel of the VM-83 unit, including power and output.
Illustrates the side view of the VM-83, showing grip and prop-up feet.
Explains the various indicators and elements displayed on the VM-83 screen.
Details how to power the VM-83 unit using batteries or an AC adapter.
Provides instructions on how to properly insert and handle batteries in the VM-83 unit.
Information on connecting and using the optional AC adapter for the VM-83 unit.
Instructions on how to use the prop-up feet to tilt the VM-83 unit for better viewing.
Guidance on selecting the appropriate piezoelectric or servo accelerometer for the VM-83.
Instructions for connecting piezoelectric and servo accelerometers to the VM-83 unit.
Details on setting the INPUT SELECT switch on the VM-83 to choose the input source.
Step-by-step guide for performing accelerometer sensitivity calibration on the VM-83.
Details the procedure for turning on the VM-83 unit and its initial settings.
Instructions for selecting the measurement mode (acceleration, velocity, displacement) on the VM-83.
Guidance on setting the display characteristics (RMS, EQPEAK, EQP-P) for the VM-83.
Instructions for setting the high-pass filter for various accelerometer types on the VM-83.
Instructions for setting the low-pass filter for various accelerometer types on the VM-83.
Details on how to set the appropriate level range for measurements on the VM-83.
Explains how to navigate and configure various settings using the menu system of the VM-83.
Procedure for calibrating the VM-83 unit, including AC and DC output signals.
Explains the maximum value hold function and how to use it on the VM-83.
Details the peak hold function and how to set and use it on the VM-83.
Describes the function and operation of the comparator in the VM-83, including output signals.
Details how to set the comparator level threshold, including its relation to the bar graph.
Explains settings for auto reset, delay time, and buzzer for the comparator function.
Details the three methods for resetting the comparator output (auto reset, HOLD RESET, COMP ON/OFF).
Describes the elements of the comparator output: buzzer, LCD flashing, and open collector circuit.
Lists the printer models compatible with the VM-83 for hard copy output.
Step-by-step guide to activate and start the printer operation for the VM-83.
Instructions on how to stop the printer operation and disconnect the cable.
Details DIP switch settings for compatible printers CP-11, CP-10, and DPU-414.
Provides a sample of the data output format when printing from the VM-83.
Explains the basic principles of the VM-83's serial interface, including transfer protocol and cable types.
Details the differences and operation between local and remote modes for controlling the VM-83.
Instructions for preparing and connecting the VM-83 to a computer via the serial interface.
Details the command structure, protocol, and basic commands for controlling the VM-83 via serial interface.
Covers error handling procedures and control operations when the VM-83 is in remote mode.
Summarizes the allowable remote mode commands across various operation conditions of the VM-83.
Explains how to connect multiple VM-83 units to a single computer using SC-31M/SC-31S adapters.
Details how to send commands to a single VM-83 unit or to all connected units simultaneously.
Provides information on noise levels and measurement ranges for different accelerometer inputs and modes.
Explains the concept of group delay introduced by the VM-83's signal processing.
Details the procedure and dimensions for mounting the VM-83 unit in a rack.
Describes various methods for installing the accelerometer to the measurement object, including precautions.
Provides details on the numeric range and resolution of the digital display on the VM-83.
Explains the aliasing effect in digital signal processing and how the VM-83's filter counters it.
Presents response curves for high-pass and low-pass filters for piezoelectric and servo accelerometers.
Describes the VM-83PB1 software package for Windows, used for controlling the VM-83 and managing data.
Details the input sections for different accelerometers and the available measurement modes (ACC, VEL, DISP).
Lists the measurement ranges for various accelerometer types, sensitivities, and filter settings.
Details the available filters (HPF, LPF) and display characteristics (RMS, EQPEAK, EQP-P) for the VM-83.
Explains maximum value hold, peak value hold, and the detailed settings of the comparator function.
Describes the various display functions and the accelerometer sensitivity and output calibration procedures.
Details the specifications for AC and DC outputs, including voltage, impedance, and accuracy.
Provides detailed noise level data for different measurement conditions and accelerometer types.
Graphical representation of measurement ranges for servo accelerometer (acceleration, velocity, displacement).
Lists general specifications including operating conditions, power requirements, dimensions, weight, and interface details.
Lists the supplied and optional accessories available for the VM-83 unit.
Provides a dimensional drawing of the VM-83 unit with key measurements.