EasyManua.ls Logo

Rion VM-83 User Manual

Rion VM-83
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTRUCTION MANUAL
Vibration Meter
VM-83
3-20-41 Higashimotomachi, Kokubunji, Tokyo 185-8533, Japan
www.64817.com
www.64817.com
Question and Answer IconNeed help?

Do you have a question about the Rion VM-83 and is the answer not in the manual?

Rion VM-83 Specifications

General IconGeneral
BrandRion
ModelVM-83
CategoryMeasuring Instruments
LanguageEnglish

Summary

Controls and Features

Front Panel

Details the various buttons, connectors, and indicators on the front panel of the VM-83 unit.

Rear Panel

Details the connectors and ports located on the rear panel of the VM-83 unit, including power and output.

Side Panel

Illustrates the side view of the VM-83, showing grip and prop-up feet.

Display

Explains the various indicators and elements displayed on the VM-83 screen.

Outline

Preparations

Power Supply

Details how to power the VM-83 unit using batteries or an AC adapter.

Inserting Batteries

Provides instructions on how to properly insert and handle batteries in the VM-83 unit.

AC Adapter

Information on connecting and using the optional AC adapter for the VM-83 unit.

Using the Prop-up Feet

Instructions on how to use the prop-up feet to tilt the VM-83 unit for better viewing.

Selecting an Accelerometer

Guidance on selecting the appropriate piezoelectric or servo accelerometer for the VM-83.

Connecting the Accelerometer

Instructions for connecting piezoelectric and servo accelerometers to the VM-83 unit.

Setting the INPUT SELECT Switch

Details on setting the INPUT SELECT switch on the VM-83 to choose the input source.

Accelerometer Sensitivity Calibration

Step-by-step guide for performing accelerometer sensitivity calibration on the VM-83.

Measurement

Power-On

Details the procedure for turning on the VM-83 unit and its initial settings.

Measurement Mode Setting

Instructions for selecting the measurement mode (acceleration, velocity, displacement) on the VM-83.

Display Characteristics Setting

Guidance on setting the display characteristics (RMS, EQPEAK, EQP-P) for the VM-83.

High-Pass Filter Setting

Instructions for setting the high-pass filter for various accelerometer types on the VM-83.

Low-Pass Filter Setting

Instructions for setting the low-pass filter for various accelerometer types on the VM-83.

Level Range Setting

Details on how to set the appropriate level range for measurements on the VM-83.

Menu Settings

Explains how to navigate and configure various settings using the menu system of the VM-83.

Calibration

Procedure for calibrating the VM-83 unit, including AC and DC output signals.

Maximum Value Hold

Explains the maximum value hold function and how to use it on the VM-83.

Peak Hold

Details the peak hold function and how to set and use it on the VM-83.

Comparator

Comparator Operation

Describes the function and operation of the comparator in the VM-83, including output signals.

Comparator Level Settings

Details how to set the comparator level threshold, including its relation to the bar graph.

Comparator Function Settings

Explains settings for auto reset, delay time, and buzzer for the comparator function.

Comparator Reset Operation

Details the three methods for resetting the comparator output (auto reset, HOLD RESET, COMP ON/OFF).

Comparator Output

Describes the elements of the comparator output: buzzer, LCD flashing, and open collector circuit.

Printer

Printer Compatibility

Lists the printer models compatible with the VM-83 for hard copy output.

Activating Printer Operation

Step-by-step guide to activate and start the printer operation for the VM-83.

Stopping Printer Operation

Instructions on how to stop the printer operation and disconnect the cable.

Printer DIP Switch Settings

Details DIP switch settings for compatible printers CP-11, CP-10, and DPU-414.

Printer Output Sample

Provides a sample of the data output format when printing from the VM-83.

Serial Interface

Transmission Principle

Explains the basic principles of the VM-83's serial interface, including transfer protocol and cable types.

Local and Remote Modes

Details the differences and operation between local and remote modes for controlling the VM-83.

Serial Connection Preparation

Instructions for preparing and connecting the VM-83 to a computer via the serial interface.

Transfer Protocol and Commands

Details the command structure, protocol, and basic commands for controlling the VM-83 via serial interface.

Error Processing and Control

Covers error handling procedures and control operations when the VM-83 is in remote mode.

Remote Command Usage

Summarizes the allowable remote mode commands across various operation conditions of the VM-83.

Multi-Unit Communication

Explains how to connect multiple VM-83 units to a single computer using SC-31M/SC-31S adapters.

Single and All Unit Control

Details how to send commands to a single VM-83 unit or to all connected units simultaneously.

Technical Information

Noise Level and Measurement Range

Provides information on noise levels and measurement ranges for different accelerometer inputs and modes.

Group Delay

Explains the concept of group delay introduced by the VM-83's signal processing.

Rack Mounting

Details the procedure and dimensions for mounting the VM-83 unit in a rack.

Accelerometer Installation Methods

Describes various methods for installing the accelerometer to the measurement object, including precautions.

Display Range Information

Provides details on the numeric range and resolution of the digital display on the VM-83.

Aliasing Effect Explanation

Explains the aliasing effect in digital signal processing and how the VM-83's filter counters it.

Filter Characteristics

Presents response curves for high-pass and low-pass filters for piezoelectric and servo accelerometers.

VM-83PB1 Software

Describes the VM-83PB1 software package for Windows, used for controlling the VM-83 and managing data.

Specifications

Input Section and Measurement Modes

Details the input sections for different accelerometers and the available measurement modes (ACC, VEL, DISP).

Measurement Ranges

Lists the measurement ranges for various accelerometer types, sensitivities, and filter settings.

Filter and Display Settings

Details the available filters (HPF, LPF) and display characteristics (RMS, EQPEAK, EQP-P) for the VM-83.

Hold Functions and Comparator

Explains maximum value hold, peak value hold, and the detailed settings of the comparator function.

Display Functions and Calibration

Describes the various display functions and the accelerometer sensitivity and output calibration procedures.

Output Specifications

Details the specifications for AC and DC outputs, including voltage, impedance, and accuracy.

Noise Level Specifications

Provides detailed noise level data for different measurement conditions and accelerometer types.

Measurement Range Graphs

Graphical representation of measurement ranges for servo accelerometer (acceleration, velocity, displacement).

General Specifications

Lists general specifications including operating conditions, power requirements, dimensions, weight, and interface details.

Accessories

Lists the supplied and optional accessories available for the VM-83 unit.

Dimensional Drawing

Provides a dimensional drawing of the VM-83 unit with key measurements.

Related product manuals