1 Introduction
MANUAL TME400-VCF · EN08 · July, 01
st
2021
38
The TME400 is equipped with permanently lubricated bearings up to a nominal diam-
eter of DN150 as standard. Nominal diameter of DN200 or higher are provided with
an integrated lubricating device. Optionally, the TME400 can also be equipped with
the "small oil pump" lubricating devices for DN25 to DN150 versions.
The type of lubricating device and the lubricant requirement depend on the nominal
diameter and the pressure level:
Nominal
diameter
Pressure classes
Lubricating device
Lubricant require-
ment
DN25-DN150
All pressure classes
As necessary (see below) optional
small oil pump
(push-button operated)
Every 3 months
6 strokes
DN200
All pressure classes
Small oil pump
(push-button operated)
Every 3 months
6 strokes
DN250
PN10 to PN16
ANSI 150
DN250
PN25 to PN100
ANSI300 toANSI600
Large oil pump
(lever operated)
Every 3 months
2 strokes
> DN300
All pressure classes
Also observe the notice plate on the housing.
In unfavorable conditions, e.g. with an accumulation of water and hydrocarbon con-
densate, as well as dust-laden gases, more frequent lubrication is recommended,
even daily in extreme cases (e.g. with continuous condensate formation).
Note
Recommended lubricating oil:
Shell Tellus S2 MA 10 or another oil with 2 to 4°E at 25°C.