4 Operation
MANUAL TME400-VCF · EN08 · July, 01
st
2021
61
4.3.
Equations in the TME400
The TME400 enables calculation of different values from the measured data and in
the data entered in the TME400. For a better understanding, some variables and for-
mula in this chapter are presented in advance; other equations and definitions of pa-
rameters are found in the chapter 4.3.3. Coordinates in context.
4.3.1.
Variable description
Formula symbol
Units
Name
q
m
m³/h
Operating volume flow at
measurement conditions
f
V
Hz
Frequency of the volume
transmitter
K
V
I/m³
Meter factor
V
m
m
3
Operating volume at
measurement conditions
P
V
Nondimensional (1)
Volume pulse
K
Z1
m
3
/I
Meter factor
(only for output contacts)
q
n
m
3
/h
Standard volume flow at normalized
condition
Vn
m
3
Standard volume at normalized
condition
Zu(p, T)
Nondimensional (1)
Conversion factor
K
Z2
m
3
/I
Meter factor
(only for output contacts)
p
bara, (barg, kg/cm2)
Measured pressure (absolute)
p
n
bara, (barg, kg/cm2)
Pressure in standard state
(=1.01325 bar absolute)
T
°C
Measuring temperature
T
K
K
Measuring temperature in Kelvin
T
n
K
Temperature in standard state
(= 273.15 K)
K
Nondimensional (1)
Compression factor
Z
Nondimensional (1)
Real gas factor
Z
n
Nondimensional (1)
Real gas factor in standard state
(calculation for Z and Z
n
takes place
according to GERG-88 in
accordance with G9)