4 Operation
Manual TME400-VMF · EN02 · 2018 September 6th
54
4.3.
Equations in the TME400
The TME400 enables calculation of different values from the measured data and in
the data entered in the TME400. For a better understanding, some variables and
formula in this chapter are presented in advance; other equations and definitions of
parameters are found in the chapter 4.3.3. Coordinates in context.
4.3.1.
Variable description
Formula symbol
Units
Name
q
m
m
3
/h
Operating volume flow at
measurement condition
f
V
Hz
Frequency of the volume transmitter
K
V
I/m3
Meter factor
V
m
m
3
Operating volume flow rate at
measurement condition
P
V
Nondimensional (1)
Volume pulse
K
Z1
m
3
/I
Meter factor (only for output contacts)
K
Z2
m
3
/I
Meter factor (only for output contacts)
4.3.2.
Standard formula
Variables presented from the previous chapter can be used for the basic equation for
the volume flow at measurement conditions:

(V


󰇜

Table of Contents